Luminaire conclusions
To meet various design requirements, three different luminaire conclusions are available for recessed downlights.
Standard ring
The basis is a particularly narrow standard ring with a recessed reflector.
Changing ring system
The changing ring system is flexible and multifunctional. The luminaire is delivered with an easy-to-assemble base ring and can be combined with many different accessories. The luminaire is delivered with a fixed ring. A separate cover ring is fastened by a bayonet lock.
Trimless-System
A special highlight is the plastered-in installation of luminaires. Our trimless system enables discreet, ceiling-flush or slightly recessed luminaire mounting. This requires a separately ordered plastering frame.
The trimless mounting system
The Trimless mounting system is used if the downlights should be an integral component of the architecture. The system perfects this contemporary design concept thanks to its completely frameless luminaire mounting.
The Trimless system features optimised versions for various ceiling systems and on-site situations. This ensures that architectural design concepts can be implemented without technical problems.
The trimless installation in cast concrete ceilings can be realised using specially developed cast-in housings. The use of a variable core element means this is also possible with bare concrete ceilings.
Trimless, flush
The plastering frame is covered by the lip of the reflector. The reflector edge sits in a slight recess and finishes flush with the ceiling.
Trimless, recessed
Edgeless installation using a plastering frame with a mounting sleeve. This sleeve is plastered over and painted in the final ceiling colour on-site.
Plaster mounting
Luminaire adapted to suit the ceiling system using a separate mounting frame. Optionally for flush installation or recessed installation. The plastering frame is fixed in the ceiling cut-out that was produced on-site and is secured using drywall screws. Fitting to the ceiling system is performed on-site. Luminaire housing for subsequent installation into finished ceiling.
Concrete housing
Concrete housing
The use of concrete housings allows recessed-mounted luminaires to be harmoniously integrated into the ceiling. Special adaptations also enable specific stress requirements to be met. This includes extended concrete inlets up to a maximum of 35mm in order to guide the armouring underneath the fitting. Flat or round fittings (with highly reduced volume) are available, depending on the ceiling situation. If round concrete castings are used, only specially adapted downlights can be used.
Specification
Sturdy one-piece housing made of galvanized sheet steel with a slanted concrete run. 2 to 4 entries for conduit. Attached throat can be extended as required. Maximum height 35mm. Fixing tabs for nail fastening to the wooden formwork. When installing in bare concrete ceilings, fixing with internal centring discs must be provided. Please order separately.
Integration into any system
Differing ceiling systems require different mounting solutions. For integrative installation into strip ceilings we offer the possibility of mounting the desired downlight discreetly into the existing system – whether this is a round or angular construction.
Almost any type of existing ceiling system can be used without major effort. We would be pleased to inform you about technical details and specifications following a brief consultation.
Add-on modular plate
The integration of recessed luminaires into M100 panel ceilings is made possible withmodular panels. (Other ceiling systems available on request.) The modular panels are mounted into the ceiling construction without tools. The downlight is subsequently mounted into the ceiling section. When using the add-on modular panels the luminaire ring is replaced by this modular panel. The luminaire cover ring therefore becomes redundant.
Before ordering please consult us for technical details.
Frame for semi-recessed mounting
Reduction of recessing height due to semi-recessing frame up to 40mm possible. Project-related supply of appropriate tilting adaptors for recessed luminaires in slant ceilings is possible.
Semi-recessed mounting is only possible with changing cover ring system.
Modular plate for panel ceilings
3-field 2-field
Perfect light – perfect protection
In certain applications, electronic components must be specifically protected. Our glass inserts provide this protection. All glass inserts feature increased splash water protection. When installed in closed ceiling systems, luminaires with permanently bonded glass covers attain protection mode IP 43 from below.
Safety lighting
Independent luminaire inserts for emergency and safety lighting can be implemented in the downlights. Integration is with or without single battery in non-maintained operation. The wide spectrum of system elements covers various solutions for emergency lighting in case of mains failure, as well as safety markings for designating escape paths in maintained operation and directive luminaires. The simple inspection possibility of supplementary elements makes use of single batteries highly simple.
Rescue signs and guidance signs
Additional signs can be easily integrated in continuous circuits or into reference luminaires by using optical lighting accessories.
LED Emergency Module
Specific components such as monitoring modules, AC/DC switching points, address modules and individual batteries can be integrated for the emergency lighting function.
Emergency lighting unit:
Single battery with control LED
Monitoring component
Change-over relays
Charge monitoring
The charge control lights up upon connection to the power network. The integrated emergency light battery is correctly charged. The multi-level charging system enables charging behaviour matched to the battery. The three methods of charging (initialisation charging, rapid charging and maintenance charging) are activated automatically.
Normal operation
The downlight is switched on and the charge control lights up. The battery is also continuously charged in normal operation.
Emergency light supply
The specified functional test is implemented directly on the luminaire without tools at the freely accessible push-button.